Versionshinweise
v1.5.0
New Features
Peak shaving control point can now be configured within the peak shaving operation mode template
Users can now define different control points for each Peak Shaving operation mode. To do this:
Navigate to Operations Management.
Create a new task of type Peak Shaving.
Specify the desired control point (e.g. 30 kW) in the designated input field
Save the task
Important Notes:
Pre-existing modes: All existing Peak Shaving operation modes will default to the control point defined under System Settings → Grid Connection Point.
EVCS Load Management Limit: The control point under System Settings → Grid Connection Point remains the upper limit for EVCS Load Management.
Multi-Use operation mode: The integration of control points into the Peak Shaving template is not yet available for the Multi-Use operation mode. In this mode, the global control point still applies as both the EVCS Load Management limit and the Peak Shaving control point.
This update gives you greater flexibility to tailor Peak Shaving to your specific operational needs
Mobile Accessibility for Operations Management
The Operations Management page is now fully functional on mobile devices.
Users can now seamlessly access the EMS, view details, and make changes in Operations Management directly from their mobile phones. This enhancement ensures greater flexibility and accessibility for on-the-go operations.
Battery Cycle count added to BMS Details
The BMS Details section now includes the total number of full battery cycles for batteries connected to the respective BMS.
To view this information, navigate to Storage → IBU → BMS, where the battery cycle count is now displayed. This update provides better insights into battery usage and performance.
Pramac Battery Inverter 90K Integration
The Pramac Battery Inverter 90K (PBI 90K) is now supported and can be added via the Device Manager for use within the EMS.
This enhancement expands compatibility and functionality within the system.
Pylontech Powercube M5 BMS Integration
The Pylontech Powercube M5 BMS is now supported and can be added via the Device Manager for use within the EMS.
This enhancement expands compatibility and functionality within the system.
Bug fixes
German Translations: Added to the Email Alerts section under System Settings → System State → Email alerts
Inverter Error Classification: Multiple inverter errors previously labeled as "Unknown Error" have been corrected in both notifications and the Inverter Error Details section.
v1.4.21
New Features
Ability to receive system notifications via email
EMS users can opt to receive system notifications by email. This can be enabled from System Settings > System State > Email Alerts. Users have the option to choose the type of email alerts they wish to receive (information, warning, or error), specify the email addresses of the intended recipients, and save their selections. For each selected notification type, when the system generates a notification, all designated recipients will receive an email. Please refer to the sample screenshot below for reference:
New Device Integration: SMA Data Manager M
The SMA Data Manager M can now be used within the EMS as a smart meter, specifically for photovoltaic systems. Within the EMS, it functions like any other smart meter for PV. Power and energy readings from the device are being displayed in various areas of the EMS where photovoltaic data is relevant: Dashboard, Reports, Photovoltaic (Overview, Details, Reports).
Notifications for inverter and BMS errors
EMS users will receive notifications for inverter and BMS errors within the UI as well as via email.
Daily energy values displayed next to the legend in the Overview chart
EMS users are now able to see the daily energy values displayed next to the legend in the Reports > Overview chart for the following data points:
Grid consumption
Grid feed-in
Charging
Discharging
PV production
Consumption
EVCS
The values for Grid feed-in, Grid consumption, PV production, and Consumption will continue to be displayed if the user selects Month, Year, or Overall reports.
Please note that these values are refreshed hourly.
Please refer to the sample screenshot below for reference:
Changes
REST API (Cloud + local): Control endpoint updated
The Control endpoint has been updated so that:
If a charge request exceeds the maxChargeLimit, the system charges at the maxChargeLimit and counts the request as valid, extending the 5-minute period for further requests.
If a discharge request exceeds the maxDischargeLimit, the system discharges at the maxDischargeLimit and also counts the request as valid, extending the 5-minute period for further requests.
Allow to enter a TCP port for TCP connected devices over UI
When a TCP connected device is being created or updated in the EMS, the user can now enter a TCP port number under the Interface section in order to be able to add devices which do not operate on the standard port.
See below image for reference:
Enhanced mobile views for pages: Dashboard, Notifications and Devices
The Dashboard page, when used on a mobile device, has been updated to show the energy monitor, similar to the desktop version. See screenshot below:
The Notifications and Devices pages have been also updated to better suit the mobile device screen size. Please see the below screenshots for reference:
Notification types
The Notifications page now displays the type of the notification which are either:
Error
Warning or
Information
Until this change, every notification was of type “Information”.
Carlo Gavazzi smart meter setup - Note
The below note appears when a Carlo Gavazzi smart meter is created. Without setting the proper application within the settings of the device, the functionality of the meter readings cannot be assured.
Reports show only PV values higher or equal to zero
In the Reports section, the charts have been revised to display only PV production values that are zero or greater. Any values that were previously negative will now be represented as zero.
Bug fixes
Alpitronic HYC EVCS - energy data values corrected
The Alpitronic HYC EVCS data has been updated for accuracy, with a correction factor of 10 applied. As a result, the values displayed in the Reports and Charging Stations sections for Alpitronic HYC EVCS will now reflect the correct figures.
Example:
EnerCharge EVCS - energy data values corrected
The way energy data from EnerCharge EVCS is read from the devices has been corrected. As a result, the values displayed in the Reports and Charging Stations sections for EnerCharge EVCS will now reflect the correct figures.
Inverter details: grid frequency shown with decimal places
The display of grid frequency value, under Storage > Inverter details has been updated to have two decimal places. Before this change, the value was displayed without the decimal places.
Autarky set to 100 on negative load
Before this change, when the load value was negative, the autarky was displayed as zero. Now, when the load is negative, autarky is 100%, this being visible on the dashboard.
v1.3.9
New Features
Local Modbus TCP interface
The EMS offers the capability to interact with the PSEC via a new local Modbus interface. This feature allows reading and writing certain registers. For details, please refer to the technical documentation.
In order to offer an enhanced user experience when interacting with the EMS for setting up local interfaces, the previously named Local API tab under System Settings > IT Network is now called Local Interfaces and it presents information and options on the preexisting Local REST API as well as the new local Modbus interface. The information and the controls for the REST API have not changed. A new sub-section was added for information and controls on the Modbus interface. In order to use this interface for reading registers, the Read access toggle needs to be enabled. In order to use this interface for writing registers, the Write access toggle needs to be enabled and current operation mode must be External Control.
The page now looks like in the screenshot below:
New UI for Inverter and BMS including error states
In order to enhance the user experience and to provide the place where to display Inverter and BMS errors, under Storage > Details there is an updated user interface that displays together (under the Status page) the information about the Inverter and the BMS as well as the devices states. See a sample screenshot below:
The BMS, Inverter and Settings tabs have been removed. The Maintenance tab remains as before.
In case of errors, near the status of the Inverter or BMS, there is a Details button displayed.
When clicked, a pop-up window is displayed, listing the current errors present in the Inverter or the BMS. See sample screenshots below:
Introduction of energy consumption values in the dashboard and report charts
The EMS dashboard now has a new widget that displays the energy consumption of the day (up until now). See sample below:
Also, in the Overview reports (under the Reports section of the EMS), in the Month, Year and Overall reports, the Consumption data is displayed. See sample below:
Ability to announce planned maintenance in the UI
The EMS now supports informational messages such as announcing planned maintenance time. When enabled, these messages will be shown on each page of the EMS, in the Portal and Edge Cloud UI as well. See below a sample screenshot:
During downtime, when the users will access the EMS, they will be redirected to a maintenance page informing them about ongoing maintenance work. The maintenance page looks like this:
Changes
Cycle loop optimization
Improved control loop to reduce cycle time from ~5 seconds to 2-3 seconds (depending on the grid meter communication interface and protocol).
Performance enhancements
The EMS performance and overall stability has been improved.
Bug Fixes
Cloud UI - Edge
The Photovoltaic > Details page now displays the status of the PV meter correctly, being consistent with the status under Devices list.
Local edge
In the Local edge, under User Menu, the My Profile menu item was removed and the missing Language menu item was re-added.